Titanium-Zinc Rainwater Diverter with Valve Ø80, Ø100, Ø120 mm

Titanium-zinc rainwater diverter with 3/4″ brass Garden valve and connection hose for round downpipes Ø80, Ø100 and Ø120 mm – overflow returns to the downpipe automatically.

Description

A titanium-zinc rainwater diverter (rain collector) is fitted into a round downpipe and sends rainwater through a brass 3/4" Garden valve and connection hose to a water butt or tank; once the tank is full, the overflow returns to the downpipe. PROTEC manufactures it in series by pressing and CNC bending at its plant in Chróścice, for downpipes Ø80, Ø100 and Ø120 mm.

Titanium-zinc rainwater diverter - technical data

Parameter Value
Material Titanium-zinc sheet, 70-100 years service life
Valve Brass Garden 3/4" with connection hose
Diameters Ø80 / Ø100 / Ø120 mm round downpipe
Manufacturing Pressing and CNC bending - repeatable dimensions across the series
Set includes Diverter + connection hose with brass connectors
Certificates ISO 9001:2015, ISO 14001:2015 (TÜV Rheinland)

How does the rainwater diverter work?

  • Automatic collection - during rain, water flows through the brass valve and hose to the tank or water butt.
  • Automatic overflow - when the tank is full, excess water returns to the downpipe and drains by gravity, with no manual operation.
  • Tank away from the wall - the connection hose lets the tank stand several metres from the downpipe.
  • Winter - close the valve and disconnect the hose, so water drains freely down the downpipe.

For distributors and OEM buyers

Titanium-zinc components from Poland - the diverter is aimed at gutter system distributors, builders' merchants and OEM manufacturers. PROTEC supplies trial batches and contract deliveries, for serial and one-off orders. Send an enquiry with quantity and specification.

FAQ - titanium-zinc rainwater diverter

How far from the downpipe can the rainwater tank stand?

Thanks to the connection hose with brass connectors, the tank can stand several metres from the downpipe - it does not have to be placed directly against the building.

What should I do with the diverter in winter?

Before winter, close the brass valve and disconnect the hose. Water then drains freely down the downpipe without the risk of freezing in the hose or tank.

Why a titanium-zinc diverter instead of plastic?

It keeps the installation in one material with a titanium-zinc gutter system, so there is no electrochemical corrosion at the joint. With a 70-100 year service life it does not need replacing during the life of the gutter system.